AC Heating Domestic Products Heat Pump Convert AW12/R32

Heat Pump Convert AW12/R32

Characteristics

A+++
Heating output of heat pump: 11,9 kW (A2W35)
Standard application: In low-energy houses, newbuilds with heat loss between 6.5 - 9.0 kW, DHW, pool heating
Residential area:
AW9-polep
Max. heating output kW 12,2
Min. heating output kW 3,1
Nominal heating output kW 11,9
Max. power consumption kW 3,8
COP (A7W35)* - 4,6
COP (A2W35)* - 3,5
SVT code - 20045

* Accredited to perform tests in accordance with standard EN 14511, EN 14825, EN 16147

Power supply v-f-Hz 230-1-50
Required circuit breaker char. A/f B20/1
Max. electrical current A 16,3
Starting electrical current A 3,5
Max. operated power kW 3,8
Sound pressure level at an average heating output of 3 m dB(A) 36
Sound pressure level at an average heating output of 5 m dB(A) 32
temperature of heating water 35°C temperature of heating water 55°C
SCOP 4,42 3,21
Energy efficiency class A+++ A++
Tbivalent* -10 °C -8 °C
Pdesign** 8,1 kW 7,7 kW
Tdesign*** -10 °C -10 °C

* outside temperature of switching on of the bivalent source

** heat loss of the house

*** outside temperature relevant to the value of Pdesign

Outdoor unit

A 900 mm
B 795 mm
C 320 mm
D 600 mm
E 365 mm
F 30 mm
G 150 mm
H 50 mm
I 10 mm

Indoor unit

A 600 mm
B 600 mm
C 200 mm
D 105 mm
E 195 mm
F 80 mm
G 45 mm
H 105 mm
I 235 mm
J 30 mm
K 555 mm
L 555 mm
M 8 mm
N 1"
O 5/8"
P 3/8"

  • Flexible
    XCC allows to set and control individual elements of the heating system.
  • Smart
    The system always finds the most effective option for your current settings.
  • Simple
    Don´t worry about complicated algorithms. Control the whole system with an user-friendly interface.

References

Family Home in Dungarvan, Co. Waterford

House type: Reconstruction
Residential area: 140 m2
Address: Dungarvan, Co. Waterford

More information

Family home in Portumna, Co. Galway

House type: Reconstruction
Address: Coolderry, Portumna, Co. Galway

More information

Similar products

AW9-polep

Heat Pump Convert AW9/R32

For low - energy houses with the heat loss between 5,0 - 8,0 kW (measured at - 5 °C outside temperature).  Expected heating cost: radiators, radiators/underfloor heating - usually up to 500€ per year underfloor heating only - usually up to 450€ per year  
AW14-polep

Heat Pump Convert AW14/R32

For family houses with the heat loss between 8,0 - 12,0 kW (measured at - 5 °C outside temperature).  Expected heating cost: radiators, radiators/underfloor heating - usually up to 700€ per year underfloor heating only - usually up to 600€ per year
AW16-polep

Heat pump Convert AW16/R32

For family houses with the heat loss between 11,0 - 16,0 kW (measured at - 5 °C outside temperature).  Expected heating cost: radiators, radiators/underfloor heating - usually up to 1.000€ per year underfloor heating only - usually up to 850€ per year

What is the price of a heat pump?

We will prepare a proposal for you